Layflat Hose Pressure Drop Calculator
Work out how much pressure a hose loses over a given diameter, flow rate and run length. Friction loss eats working pressure — a hose that is fine at the pump can deliver nothing useful at the far end of a long run, even when the pressure rating is right.
Friction loss rises with flow and length, and falls as diameter grows. The calculator gives the bar-per-100 m figure, the total loss over your run and the water velocity, so you can see whether the run chokes the pump.
Metric or imperial. Runs in your browser. No signup required.
Layflat Hose Pressure Drop Calculator
Enter the hose diameter, flow rate and run length. Results update as you type — pressure drop per 100 m, total loss over the run and water velocity. All calculations run in your browser.
Pressure Drop Results
Enter your hose details to calculate pressure drop.
- Friction loss per 100 m
- Friction loss over the run
- Water velocity
- Hose diameter
- Fittings & elevation
Friction Loss
hf = 10.67 × L × Q^1.852 ÷ (C^1.852 × d^4.87)
Hazen–Williams estimate, C = 140, clean water at 20°C.
Pressure Conversion
pressure (bar) = head (m) × 0.0981
1 bar ≈ 14.5038 psi · 1 m³/h ≈ 4.403 US gpm.
Every figure on this page is an indicative Hazen–Williams estimate for clean water at 20°C. The batch test report for the specific grade is the figure to buy against.
Layflat Hose Friction Loss at a Glance
The table below is the calculator in static form. Read your diameter and flow rate, and the last column is the pressure you lose for every 100 metres of run. These figures assume a new, clean PVC hose (C ≈ 140) — an old, dirty or partially kinked hose flows worse.
Small Diameter, Steep Loss
Diameter enters the formula to the power of about 4.87 — a small increase cuts the loss a lot. The loss is steep at small diameters and shallow at large ones.
Doubling Flow Does Not Double Loss
Friction loss rises roughly to the power of 1.85 with flow. A small increase in flow near the top of a hose’s range adds a lot of pressure loss.
1.5–3 m/s Is the Working Band
Below 1.5 m/s the hose is under-loaded for its size; above 3 m/s the friction loss climbs sharply and the hose wears faster. Step up a diameter and the loss falls more than proportionally.
| Diameter (nominal) | Flow rate | Velocity | Friction loss (bar / 100 m) |
|---|---|---|---|
| 2″ (50 mm) | 20 m³/h | ~2.7 m/s | ~1.45 |
| 3″ (76 mm) | 45 m³/h | ~2.8 m/s | ~0.94 |
| 4″ (102 mm) | 60 m³/h | ~2.0 m/s | ~0.38 |
| 6″ (152 mm) | 120 m³/h | ~1.8 m/s | ~0.20 |
How to read it: the loss is not a flat rate. The 2″ hose loses about 1.45 bar per 100 m while the 6″ hose loses about 0.20 bar at the flows shown. Every figure here is an indicative Hazen–Williams estimate (C = 140, clean water, 20°C) — a sizing estimate, not a test result. Scroll horizontally on smaller screens.
On smaller screens, scroll horizontally to view all columns.
Working Pressure and Friction Loss Move in Opposite Directions
Working pressure falls as diameter rises, while friction loss falls as diameter rises. The two move in different directions — which is why a hose is sized on both at once, not on either alone.
The Layflat Caveat
A layflat hose is round under pressure but elliptical or flattened at low pressure, so a formula built for rigid round pipe over- or under-states the loss. The table is a sizing estimate — confirm the figure against a batch test report for the specific grade before you commit.
Layflat Hose Friction Loss at a Glance
The table is the calculator in static form. Read your diameter and flow rate, and the last column is the pressure you lose for every 100 metres of run. Every figure is a Hazen–Williams estimate for a new, clean PVC hose (C ≈ 140).
| Diameter (nominal) | Flow rate | Velocity | Friction loss (bar / 100 m) |
|---|---|---|---|
| 2″ (50 mm) | 20 m³/h | ~2.7 m/s | ~1.45 |
| 3″ (76 mm) | 45 m³/h | ~2.8 m/s | ~0.94 |
| 4″ (102 mm) | 60 m³/h | ~2.0 m/s | ~0.38 |
| 6″ (152 mm) | 120 m³/h | ~1.8 m/s | ~0.20 |
How to read it: the loss is not a flat rate. The 2″ hose loses about 1.45 bar per 100 m while the 6″ hose loses about 0.20 bar at the flows shown. Doubling the flow does not double the loss — it raises it to roughly the power of 1.85. Velocity is the warning light: below 1.5 m/s the hose is under-loaded, above 3 m/s the loss climbs sharply.
Quick Friction Loss Estimate
Enter the diameter, flow rate and run length. This is a scaled estimate based on the table above — not a substitute for the full Hazen–Williams calculation.
Sizing estimate only. An old, dirty or partially kinked hose flows worse — add margin or use a lower C value for the full calculation. The batch test report for the specific grade is the figure to buy against.
How to Use the Table
loss over the run = loss per 100 m × (run length ÷ 100)
- Find your diameter and the flow rate closest to your pump output. The last column is the loss per 100 metres.
- Multiply by the run length in hundreds of metres. A 300 m run of 4″ at 60 m³/h loses roughly 0.38 × 3 = 1.14 bar.
- Check the velocity column. Between 1.5 and 3 m/s is the working band. Above 3 m/s, step up a diameter — the loss falls more than proportionally.
- Subtract the total loss from the pump’s discharge pressure. The remaining pressure must clear the working pressure of the grade you are specifying.
These figures assume a new, clean PVC hose (C ≈ 140) on a flat run. Fittings, bends and lift add to the total and should be stated separately for a long line.
The Three Losses You Add Up
Friction is only one of three losses on a real run. Add all three, and you get the total the pump has to overcome. The sum is the total dynamic head, and the figure left after subtracting it is the one to check.
Friction Loss
Over the run length
- Source
- Hose wall
- Measured by
- Table
- Unit
- bar / 100 m
Vertical Lift
Every metre uphill
- Cost per metre
- ~0.1 bar
- 5 m climb
- ~0.5 bar
- Often
- Forgotten
Fittings
Bends and couplings
- 90° elbow
- ≈ 20 × D
- Coupling
- ≈ 5 × D
- Long run
- Noise
Total Dynamic Head
The sum of all three
- Friction
- +
- Lift
- +
- Fittings
- =
Friction loss is taken from the size and pressure table for a new, clean hose on a flat run. Vertical lift and fittings are added on top, in the same units.
Lift Is the Loss Most Often Forgotten
Every metre of uphill height costs about 0.1 bar, regardless of the hose. A 5 metre climb adds about 0.5 bar to the total, and it is easy to leave it out when the run is described as “horizontal”.
Fittings add resistance the same way. A 90° elbow counts as roughly 20 pipe diameters of equivalent length; a coupling about 5. A few fittings on a long run are noise — several on a short run are not.
Check the Figure Left After Subtraction
The pump's discharge pressure minus the total dynamic head is what actually reaches the outlet. That remaining figure is the one to check against the working pressure of the hose you are specifying.
If the margin is small, the run is working the hose close to its rating. If the remaining figure is below the working pressure you need, step up a diameter — the friction loss falls more than proportionally.
Check the Result Against the Working Pressure
A friction-loss number on its own does not answer the question. The question is whether the pump still delivers enough pressure at the far end — and that means comparing the result against the working pressure at your diameter.
Working Pressure
The rating to run at
- Select on
- Working pressure
- Never treat as
- Burst pressure
Burst Pressure
The safety margin
- Treat as
- Margin, not rating
- Never run at
- Burst pressure
Remaining pressure = Pump discharge pressure − Total dynamic head. What remains must clear the working pressure for the hose at that diameter. Burst pressure is the margin, not the rating. Confirm the grade against a batch test report.
Friction Loss Alone
A bare calculator gives the friction loss over the run. That number matters, but it does not answer whether the pump still delivers enough pressure at the far end.
Check the Remaining Pressure
Subtract the total dynamic head from the pump's discharge pressure. The figure left is the one to compare against the working pressure of the hose you are specifying.
This is the step a bare calculator leaves out. It is also the step that decides whether the hose you are about to buy actually does the job. Read the working-pressure figure for your size, then confirm the grade against a batch test report.
Frequently Asked Questions
Answers about friction loss, C factors, diameter effects and how to check the result before you buy.
How do I calculate pressure drop in a layflat hose?
Use the Hazen–Williams formula with a roughness coefficient C of about 140 for new PVC, entering the inner diameter, flow rate and run length — or read the estimate from the table above.
The result is a sizing estimate; confirm it against a batch test report for the specific grade.
What C factor should I use for layflat hose?
About 140 for new, clean PVC layflat hose, and similar for TPU. A dirty, aged or kinked hose flows worse, so use a lower value or add margin.
The C value is a roughness coefficient, not a fixed property of every hose.
How much pressure is lost in a layflat hose?
It depends on diameter, flow and length. At typical irrigation flows, roughly 0.2 to 1.5 bar per 100 metres — about 0.38 bar per 100 m on a 4 inch hose at 60 m³/h, about 1.45 bar per 100 m on a 2 inch hose at 20 m³/h.
Friction loss rises sharply as flow increases.
Does hose diameter affect pressure drop?
Yes, more than anything else. Diameter enters the friction formula to about the 4.87 power, so a small step up in diameter cuts the loss a lot.
Note the direction is the opposite of the pressure rating, which falls as diameter rises.
How long can a layflat hose run be?
There is no single limit — the run is limited by how much pressure loss the pump can absorb. A long run needs a larger diameter to keep friction loss down.
Work out the total loss (friction plus lift plus fittings) and check it against the pump and the working pressure.
Is the result accurate enough to buy on?
The table is an estimate for clean water at about 20°C, and layflat hose's non-circular shape adds uncertainty at low pressure. Use it to size the hose and to confirm the diameter, then buy against the batch test report for the specific grade.
Size Your Layflat Hose on Three Numbers
Flow rate, working pressure and friction loss move independently. This page gives you the third — the pressure lost between pump and outlet — so you can pick a diameter that neither chokes the pump nor over-specs the hose. Calculate the loss, add the lift and the fittings, then check the remaining pressure against the working pressure at your diameter. Send us the diameter, flow rate, run length and fluid — we will size the hose and send a sample.
Send Your Hose Specification