Layflat Hose Size and Pressure Chart
Working pressure is not one number on a layflat hose — it falls as diameter rises. A 2-inch heavy-duty hose runs around 10 bar; a 10-inch hose runs around 4 bar. This chart shows that relationship by diameter, so you can select on the working pressure at the size your pump and run length actually call for.
Get the number right and the hose does its job for years. Get it wrong two ways: a hose run above its working pressure fails early, and a hose over-specified for the job costs more than it needs to. The chart and the rules that follow are built to stop both mistakes.
Layflat Hose Size and Pressure Chart
The chart reads across five columns: diameter in inch and mm, working pressure, burst pressure and wall thickness. The heavy-duty PVC grade is the primary reference; light-duty runs lower and is noted below the table. Working pressure falls as diameter rises — a 2-inch heavy-duty hose runs around 10 bar, a 10-inch hose runs around 4 bar.
Select on Working Pressure
Working pressure is the pressure the hose runs at continuously. It falls as diameter rises — a 2-inch heavy-duty hose runs around 10 bar, a 10-inch hose around 4 bar. Select the hose on this figure, not on burst.
Burst Is a Safety Margin
Burst pressure is where the hose fails — for PVC layflat, typically about three times working pressure. A 10 bar hose fails around 30 bar. Treat burst as a margin, not as a rating to operate at.
The Wall Takes the Pressure
Wall thickness matters because it is the part of the hose that holds the pressure. A thicker wall at a larger diameter is not extra cost — it is what keeps the hose round instead of ballooning.
| Diameter (inch) | Diameter (mm) | Working Pressure | Burst Pressure | Wall Thickness |
|---|---|---|---|---|
| 1.5″ | 38 | 10 bar | 30 bar | ~1.5 mm |
| 2″ | 50 | 10 bar | 30 bar | ~1.5 mm |
| 2.5″ | 65 | 10 bar | 30 bar | ~1.5 mm |
| 3″ | 76 | 9 bar | 27 bar | ~2.0 mm |
| 4″ | 102 | 9 bar | 27 bar | ~2.0 mm |
| 6″ | 152 | 7 bar | 21 bar | ~2.5 mm |
| 8″ | 203 | 5 bar | 15 bar | ~3.0 mm |
| 10″ | 254 | 4 bar | 12 bar | ~3.0 mm |
Reference values for heavy-duty PVC layflat. Light-duty PVC runs lower — roughly 5 bar at 2 inch, falling to around 2 bar at 16 inch. If the job is seasonal irrigation at low pressure, the light grade costs less and does the job; if the hose gets dragged, run at pressure, or left out, the heavy grade is the safer starting point. Confirm the rated working pressure for your selected size and grade.
On smaller screens, scroll horizontally to view all columns.
Working Pressure Falls With Diameter
The pattern is the point: a 1.5 to 2.5 inch hose runs at 10 bar, a 10 inch hose at 4 bar. Select on the working pressure at the size your pump and run length actually call for — not on a single number for the whole range.
Two Ways to Get It Wrong
A hose run above its working pressure fails early. A hose over-specified for the job costs more than it needs to. The chart and the rules above are built to stop both mistakes — name the diameter and working pressure, and request a sample to check the wall and coupling fit.
How Working Pressure Changes with Diameter
The single most useful fact on this page is that working pressure falls as diameter rises. It is why a “heavy duty” label is not a pressure rating. Take two hoses from the same heavy-duty PVC grade: the 2-inch hose holds 10 bar, and the 10-inch hose, made the same way, holds 4 bar. The material did not change; the geometry did.
| Diameter (inch) | Diameter (mm) | Working Pressure | Burst Pressure | Wall Thickness |
|---|---|---|---|---|
| 1.5″ | 38 | 10 bar | 30 bar | ~1.5 mm |
| 2″ | 50 | 10 bar | 30 bar | ~1.5 mm |
| 2.5″ | 65 | 10 bar | 30 bar | ~1.5 mm |
| 3″ | 76 | 9 bar | 27 bar | ~2.0 mm |
| 4″ | 102 | 9 bar | 27 bar | ~2.0 mm |
| 6″ | 152 | 7 bar | 21 bar | ~2.5 mm |
| 8″ | 203 | 5 bar | 15 bar | ~3.0 mm |
| 10″ | 254 | 4 bar | 12 bar | ~3.0 mm |
Reference values for heavy-duty PVC layflat. A larger diameter means a larger internal surface area for the pressure to act on, and a longer wall to carry the load — so the same wall holds less pressure per unit area. Light-duty PVC runs lower.
| Diameter | Actual Working Pressure | Blanket Table Assumption | Over-Spec Factor |
|---|---|---|---|
| 2″ | 10 bar | 8–10 bar | Match |
| 4″ | 9 bar | 8–10 bar | Match |
| 6″ | 7 bar | 8–10 bar | ~1.3× |
| 8″ | 5 bar | 8–10 bar | ~1.8× |
| 10″ | 4 bar | 8–10 bar | ~2.3× |
Over-spec factor compares the blanket assumption against the actual working pressure at each diameter. Selecting a 10-inch hose from a “heavy duty = 8–10 bar” table over-specs the hose by more than double. This is why the size and pressure chart is a table, not a paragraph — the answer depends on the row.
Select on working pressure, not burst. Working pressure is the pressure the hose is designed to run at continuously. Burst pressure is the point at which it fails — for PVC layflat, typically about three times working pressure. That 3× figure is not an invitation to run at burst. It is the margin that absorbs a pressure spike when a pump starts against a closed valve or a run kinks briefly.
The Rating You Run At
Working pressure is the pressure the hose is designed to run at continuously. Select the hose on this figure. A 2-inch heavy-duty hose runs at 10 bar; a 10-inch hose of the same grade runs at 4 bar.
The Margin You Don’t Run At
Burst pressure is where the hose fails — typically about three times working pressure for PVC layflat. A 9 bar hose fails around 27 bar. Treat burst as the safety margin, not the rating. Running at burst is buying a failure.
Why the Hose Holds Its Shape
The reinforcement between the PVC layers is high-tenacity polyester knit. It is what keeps the hose round under pressure and flat when drained — the difference between a hose that holds its shape and one that balloons at the first spike.
Temperature and Water-Condition Derating
The pressure ratings assume clean water at about 20°C. That assumption is worth stating because it is not always true in the field. At higher temperatures the working pressure derates, and what is moving through the hose changes its life even when the pressure is unchanged.
Every working-pressure figure in the size and pressure chart assumes this baseline. Hot water, oils, fuels, fertilisers and abrasive slurries are all different jobs.
- Ambient baseline
- ~20°C / clean water
- High-temperature derate
- Grade-specific
- Some grades at 60°C
- ~50% of rated pressure
- Non-water media
- Material selection governs
Hot Water
Baseline: 10 bar at 20°C Same hose, hot water at higher temperature
Oils & Fuels
Pressure unchanged Media changes the life of the hose
Fertilisers & Slurries
Pressure unchanged Abrasion and chemistry act together
State the Temperature and the Media Before You Order
If the hose carries hot water, state the temperature so the grade can be rated for it. If the hose moves oils, fuels, fertilisers or abrasive slurries, state the media so the material choice is made for it. A rating is only valid inside its assumption — and “clean water at 20°C” is an assumption, not a default.
Derating values are material- and grade-specific. Confirm the rated working pressure for your selected grade at the actual operating temperature and media before quoting the hose into a job.
PVC vs TPU — the Pressure Envelope by Material
Both materials do the same basic job: move water. They part ways on abrasion, cold and service life, and the choice is a cost decision more than a pressure one. Select on the conditions the hose will actually see.
Abrasion and Dragging
PVC has moderate abrasion resistance. TPU is 5–10× better. If the hose gets dragged over gravel and rock, TPU is the safer starting point.
Cold Flexibility
PVC stiffens below about 0°C and can crack. TPU stays flexible to roughly −40°C. If the hose runs through a cold season, specify TPU.
UV and Chemical Exposure
PVC lasts roughly 2–3 years outdoors with limited chemical resistance. TPU runs 5–10 years and handles oils, fuels and fertilisers.
| Property | PVC Layflat | TPU Layflat |
|---|---|---|
| Working pressure | 2–10 bar | Higher (≈7 bar and up) |
| Abrasion resistance | Moderate | 5–10× better |
| Cold flexibility | Stiffens below ~0°C Can crack in freezing conditions | Flexible to ~−40°C Suitable for cold-climate work |
| UV / weather life | ~2–3 years outdoors | 5–10 years |
| Chemical resistance | Limited Not the choice for oils or fuels | Handles oils, fuels, fertilisers |
| Weight | Moderate | Lighter at equal burst |
| Cost | Lower | Higher Usually recovered over its service life |
Both materials do the same basic job. The comparison describes the category — confirm the rated working pressure, chemical compatibility and temperature range for the specific grade you are buying. Scroll horizontally on smaller screens.
| Job Condition | PVC Is the Right Fit | TPU Is the Right Fit |
|---|---|---|
| Seasonal use | Yes Standard farm irrigation, light dewatering | Over-specified for the job |
| Cost-sensitive | Yes Lower upfront price | Higher upfront, lower long-run |
| Rough ground | Not the right fit | Yes Dragged over gravel and rock |
| Freezing conditions | Not the right fit Stiffens below about 0°C | Yes Flexible to ~−40°C |
| Fertiliser or chemicals | Not the right fit Limited chemical resistance | Yes Handles fertilisers, oils, fuels |
| Multi-season service | Replace every 2–3 seasons outdoors | Yes 5–10 years outdoors |
The higher upfront price of TPU usually comes back over its service life when the job involves abrasion, cold, chemicals or multi-season exposure. For a seasonal, low-abrasion job that stays out of freezing weather, PVC is the economical choice.
Match the Material to the Job, Not the Price Tag
The cheaper hose is not the cheaper answer if it fails in the first season. A PVC hose dragged over gravel wears through; a TPU hose on a low-abrasion seasonal job is money spent on capability the job does not use. Pick the material that matches the conditions, then compare prices within that material.
The Pressure Envelope Is Not the Whole Decision
Both materials cover a wide pressure range. The difference is what happens to the hose in the field: abrasion, cold flexibility, UV life and chemical exposure. State the conditions the hose will actually see — the ground it crosses, the temperature it runs in, the media it moves — and the material choice follows.
How to Size a Layflat Hose to Your Pump
The pressure chart answers “which size and pressure”, but the starting question is the pump. Work through these steps in order — each one narrows the choice until the diameter, pressure and material are fixed.
Start With the Pump
The pump’s rated flow (litres per minute or m³/h) sets the minimum diameter — a hose too small chokes the pump and burns power. Then measure the run length: longer runs add friction loss, which eats working pressure.
Pick Diameter, Then Confirm Pressure
Match the diameter to the flow rate and run length using the chart’s first two columns. Then read the working-pressure column for that diameter and check it clears the pump’s discharge pressure plus the friction loss on the run.
Choose the Material Last
PVC for seasonal, low-abrasion duty. TPU for abrasive, cold or long-life duty. The material choice is a cost decision — pick it once the diameter and pressure are fixed, because it does not change the size.
A pump rated at 500 L/min on a 60 m run, moving clean water at ambient temperature, resolves to a 2-inch heavy-duty hose at 10 bar working pressure in PVC. If the same job dragged the hose over gravel or ran through winter, the diameter and pressure stay the same — only the material moves to TPU.
Send Us the Flow, Run and Media
If you would rather not work the steps alone, send us the flow rate, the run length, the material you are moving and the destination port. We will size the hose, quote the grade and send a sample so you can check the wall and coupling fit.
Roll Lengths, Fittings and Testing
For the complete specification — roll lengths, fittings, applications and batch testing — ask for the product page detail or request the compliance pack. Every hose ships with the rated diameter, working pressure and material confirmed on the order.
Frequently Asked Questions
Answers about hose diameter, working pressure, burst pressure and how to read a pressure chart.
What size layflat hose do I need?
Most field irrigation runs on 2, 3 or 4 inch hose, but the right size depends on pump flow rate and run length — not on a rule of thumb. Tell us the flow rate and the distance, and we will size the hose so it does not choke the pump.
What is the working pressure of layflat hose?
Working pressure is the pressure the hose runs at continuously, and it falls as diameter rises. On heavy-duty PVC it runs from around 10 bar at 2 inch down to around 4 bar at 10 inch. Read the working-pressure column for the diameter you need.
Does layflat hose pressure change with diameter?
Yes. Working pressure falls as diameter rises because a larger diameter puts more internal surface area under pressure. A 2-inch heavy-duty hose holds about 10 bar; a 10-inch hose holds about 4 bar.
What is the difference between working pressure and burst pressure?
Working pressure is the continuous operating pressure; burst pressure is where the hose fails — for PVC layflat, typically about three times working pressure. Select on working pressure and treat burst as the safety margin.
Burst pressure ≈ 3 × Working pressure
How do I read a layflat hose pressure chart?
Find your diameter in the first column, read its working pressure and wall thickness, and check the working pressure clears your pump’s discharge pressure. The burst column is your margin, not your rating. If the water runs hot, derate from the listed figure.
What wall thickness layflat hose do I need?
Wall thickness rises with diameter — roughly 1.5 mm at the small end up to about 3 mm at 10 inch. The wall is what carries the pressure, so it is matched to the working pressure of the size, not chosen separately.
Specify Your Layflat Hose by Three Numbers
A layflat hose is specified by diameter, working pressure and material — and the order you get them in matters. Read the diameter to find the pressure, select on working pressure not burst, and choose PVC or TPU by abrasion, cold and service life. Send us the flow rate, the run length, the material you are moving and the destination port — we will size the hose, confirm the grade and send a sample.
Send Your Hose Specification